--> How much do you know about dual-channel air-conditioning box? Dual-channel air-conditioning box manufacturers to share with you-Seasons,Specialized in the production of central air conditioning
Promote The Sustainable Development Of The Enterprise By Technological Innovation And Expanding Industrial Applications.

NEWS CENTER

How much do you know about dual-channel air-conditioning box? Dual-channel air-conditioning box manufacturers to share with you

2021-11-08 12:00

How much do you know about dual-channel air-conditioning box? Dual-channel air-conditioning box manufacturers to share with you The manufacturer of the dual-channel air-conditioning box said that in summer, the traditional constant temperature and humidity air-conditioning box generally uses chilled water to cool the air through the surface cooler. Because the technical air conditioner of the cigarette factory has the dual requirements of temperature and humidity, in the process of cooling the air by the surface cooler, it will produce excessive cooling to achieve the purpose of dehumidification, and the cooling capacity of the excessive cooling part needs to be heated by steam to meet the requirements of air supply temperature and humidity.

How much do you know about dual-channel air conditioning box? Dual-channel air conditioning box manufacturers to share with you.

The manufacturer of the dual-channel air-conditioning box said that in summer, the traditional constant temperature and humidity air-conditioning box generally uses chilled water to cool the air through the surface cooler. Because the technical air conditioner of the cigarette factory has the dual requirements of temperature and humidity, in the process of cooling the air by the surface cooler, it will produce excessive cooling to achieve the purpose of dehumidification, and the cooling capacity of the excessive cooling part needs to be heated by steam to meet the requirements of air supply temperature and humidity.

The two-channel air-conditioning box manufacturer said that the secondary heating phenomenon produced by the traditional air-cooling method will waste a lot of energy, and a large amount of steam needs to be added to overcome the excessive consumption of cold energy, which does not meet the requirements of energy saving and emission reduction.

The dual-channel air-conditioning box manufacturer said that the dual-channel air-conditioning box eliminates the air cooling capacity generated by the supercooling part due to the humidity requirement of the air supply, thus meeting the temperature and humidity requirements of the air supply, improving the energy-saving potential of the air-conditioning system and meeting the requirements of energy saving and emission reduction.

The manufacturer of the dual-channel air conditioner said that the dual-channel air conditioner includes a return air fan section, an exhaust section, a new return air mixing section, a filter section A, a surface cooling section, a heating section, a humidification section, a blower section, a filter section B and a control air valve. The upper section of the exhaust section is connected to the new return air mixing section, the new return air mixing section is connected to the filter section A, and the filter section A is connected to the surface cooling section. The lower section of the exhaust section is connected with the filter section B through a partition pipe, the filter section B is connected with a control air valve, and the control air valve is connected with the heating section; a steam port is arranged above the heating section, and the steam port is connected with the humidification section; a humidification port is arranged above the humidification section, and the humidification port is connected with the blower section; an air outlet is arranged above the fan section.

The two-channel type air conditioner is provided with a temperature and humidity detecting element at an air outlet of the blower section.

As a further improvement, the ventilation area of the lower part of the exhaust section of the dual-channel air-conditioning box accounts for 15%-25% of the ventilation area of the upper part of the exhaust section.

The manufacturer of the dual-channel air-conditioning box said that the dual-channel air-conditioning box can eliminate the excessive air cooling caused by the humidity requirements of the controllable dual-channel combined air-conditioning box, so as to meet the temperature and humidity requirements of the air supply, improve the energy-saving potential of the air-conditioning system, and meet the requirements of energy saving and emission reduction. Compared with the single cold source fresh air dehumidification to eliminate the secondary heating of the air conditioner, the utility model has lower requirements for the cold source (relatively less fresh air to remove the same moisture in the air conditioner, lower requirements for the chilled water temperature, I .e. higher requirements for the quality of the cold source), lower investment and maintenance costs. (In the future, the investment and maintenance costs of the fresh air cooling and dehumidification section need to be increased).

If you need to know anything about the dual-channel air conditioner box, please contact our dual-channel air conditioner box manufacturer. We have many years of experience in this area.

 


Telephone

021-64893536

Sales R & D Center

488 Guangzhong Road, Minhang District, Shanghai

Production Base

No.26, Anfeng Information Industrial Park, Yancheng City, Jiangsu Province